Actisense NMEA 2000 Engine Monitoring Unit - Analog to NMEA2000 Engine Gateway [EMU-1-BAS]
Sale!

Actisense NMEA 2000 Engine Monitoring Unit – Analog to NMEA2000 Engine Gateway [EMU-1-BAS]

Original price was: $614.66.Current price is: $122.93.

SKU: 8279057563927 Category:

Description

NMEA 2000 Engine Monitoring Unit – Analog to NMEA2000 Engine Gateway

Share engine information on the NMEA 2000 bus.

The Actisense EMU-1 is a specialized analogue to NMEA 2000 Gateway which converts data from analogue engine gauges/senders into NMEA 2000 data. The EMU-1 enables the sharing of engine data throughout the NMEA 2000 bus. It digitizes analogue engine sensors, enabling NMEA 2000 display devices to monitor the connected engine(s) on a vessel.

The EMU-1 can monitor vital engine parameters such as temperature, pressure RPM and fluid levels from up to two engines.

The EMU-1 has a PC-based configuration tool that allows the settings inside the EMU-1 to be changed to best suit the engine it is working with, making it a flexible solution for many engine makes and models.

An Actisense PC to NMEA 2000 Gateway (NGX-1/NGT-1) is required to configure the EMU-1.

The NGX-1 or NGT-1 must be used to update the firmware, connect the Toolkit and display data on a PC for diagnostic and information purposes, using NMEA Reader. Please visit the NGX-1 page and/or NGT-1 page for product details.

Features:

  • Enables analogue signals to be converted to NMEA 2000 messages
  • Convert signals from up to two engines (that share a common ground) with a single EMU-1
  • 6 gauge / parameter inputs
  • 4 alarm inputs
  • 2 additional auxiliary inputs
  • 2 Tacho inputs
  • Customized IP65 case
  • Diagnostic LED’s
  • Wide power compatibility of 9 to 35VDC
  • No need to change an existing engine
  • Easy installation
  • Easy to configure to suit the connected engine
  • Connect signals from fluid level gauges (that share a common ground with the engine) to NMEA 2000®
  • Optional DIN rail mounting kit available
  • Total engine hours are logged by the monitoring of engine Tach (RPM) input

Technical Specifications:

Power Supply

  • Supply Voltage – 9 to 35VDC
  • Supply Current – Typically < 25mA /embed/2dhh-U43rek" frameborder="0" allowfullscreen>

Reviews

There are no reviews yet.

Be the first to review “Actisense NMEA 2000 Engine Monitoring Unit – Analog to NMEA2000 Engine Gateway [EMU-1-BAS]”

Your email address will not be published. Required fields are marked *